Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.
I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.
Biography: https://test.test.electrical-engineering-portal.com/edvard-csanyi
A substation constructed or heavily retrofitted just four to five years ago represents a marvel of modern engineering, boasting fiber-optic communications, Intelligent Electronic Devices (IEDs), and advanced control algorithms. However, this rapid technological acceleration has birthed a new, unprecedented engineering paradox:…...
Aug 10, 2026 | By Edvard Csanyi
This technical article provides an in-depth technical analysis of the Relay and Metering Panel schematics, examining the attached engineering panel design document (PDF). The panel which we’ll discuss in great detail, serves as the central command node for electrical protection,… Read more
Aug 03, 2026 | By Edvard Csanyi
The execution of a high-voltage circuit breaker trip is the most critical function within any electrical substation. In the provided schematic document for the 132kV Line-1 (=E01) Relay Panel +RP3, the trip circuits are meticulously designed to ensure absolute reliability,…...
Jul 27, 2026 | By Edvard Csanyi
This article provides a comprehensive, highly detailed technical explanation of the 132kV Gas Insulated Switchgear (GIS) Local Control Cabinet (LCC) schematics, specifically for the plant designated “132 KV GIS ELK-04 GETZ” and the equipment identified as “CONTROL CUBICLE -E1Q02”. Decoding… Read more
Jul 20, 2026 | By Edvard Csanyi
The provided schematics detail the comprehensive control, protection, metering, and operational logic for a 132/33kV, 31.5MVA Power Transformer (Transformer-1), explicitly designed by Schneider Electric for the APTRANSCO Thimmapuram substation. The architecture strictly segregates the high-voltage (132kV) and low-voltage (33kV) control… Read more
Jul 13, 2026 | By Edvard Csanyi
This comprehensive technical analysis breaks down the twenty most annoying imperfections in MV and LV switchgear, detailing the design flaws, their root causes, and the real-world operational impacts that consistently frustrate substation operators and maintenance crews. As we all know,…...
Jul 06, 2026 | By Edvard Csanyi
This technical article provides an in-depth engineering analysis of the 1000A Low Voltage Motor Control Center (MCC) panel for high-demand applications. The panel is built on the Prisma M enclosure platform and features a complex array of incoming protection, outgoing… Read more
Jun 29, 2026 | By Edvard Csanyi
The schematic drawings for the 132kV Line-1 Protection Panel (Bay-B102) provide a detailed, component-level view of how digital boolean logic is employed to govern the operation of high-voltage circuit breakers, isolators (disconnect switches), and earth switches. Operating within the framework…...
Jun 22, 2026 | By Edvard Csanyi
The technical article provides a highly detailed analysis of the Reactor Troubles Circuit schematics. It systematically breaks down the contact multiplication stage, the core mechanical protections (Buchholz, WTI, SPR), and the pressure/thermal protections (PRD, PNRV, OTI). Each component is mapped…...
Jun 15, 2026 | By Edvard Csanyi
For some substation engineers, sudden breaker tripping incidents are a favorite puzzle that demands clear, out-of-the-box thinking. However, for the majority, these events are a true nightmare with no obvious starting point for troubleshooting. However, any anomalies in circuit breaker…...
Jun 08, 2026 | By Edvard Csanyi
This technical review analyzes the core programming languages, hardware description languages, and configuration syntaxes utilized in contemporary power engineering. Emphasis is placed on their application in Intelligent Electronic Devices (IEDs), Supervisory Control and Data Acquisition (SCADA) systems, and digital substation…...
Jun 01, 2026 | By Edvard Csanyi
Today’s power engineers are expected to seamlessly navigate 200-page protection schematics, simulate complex transients using software such as ETAP, analyze and troubleshoot relay protection schematics, design robust LV distribution networks, and even leverage Artificial Intelligence to troubleshoot power quality issues…. Read more
May 25, 2026 | By Edvard Csanyi
The DELA ROSA 230kV Substation represents a critical node in high-voltage power transmission, utilizing a highly integrated outdoor Gas Insulated Switchgear (GIS) topology. The reference engineering documentation specifies a comprehensive 245kV implementation, structured predominantly around Siemens Energy’s 8DN9 and 8DQ1…...
May 18, 2026 | By Edvard Csanyi
Operating an electrical substation leaves a zero margin for error. The critical mistakes operators make, from bypassing interlocks and improper grounding to rushing and ignoring PPE — rarely stem from a lack of skill. Instead, they represent breakdowns in procedure,… Read more
May 11, 2026 | By Edvard Csanyi
This comprehensive guide serves as your master blueprint for decoding 24kV switchgear schematics. While the primary focus of this guide is the secondary wiring and automation schematics, we will break down the system layer by layer, starting with the System…...
May 04, 2026 | By Edvard Csanyi