NEMA Motor Data Calculator - Schneider Electric
NEMA Motor Data Calculator – Schneider Electric

Three Phase and Single Phase Motor

NEMA Motor Data Calculator is based on the NEC 2011.

For three-phase motor according to inputs (Voltage and Horse Power) following motor data is calculated:

  1. Full Load Amps (FLA)
  2. Wire Size
  3. PowerPact Breaker Size
  4. PowerPact Breaker Cat No.
  5. HD Switch, Nema 1 Enclosed
  6. Dual Elem Time Delay Fuse Amps
  7. NEMA Starter Catalog Number
  8. Melting Alloy Thermal Unit
  9. Nema Size Starter

For single-phase motor input is Horse Power and following information is calculated for both voltages 115V and 230V:

  1. Full Load Amps (FLA)
  2. Wire Size
  3. PowerPact Breaker Size
  4. PowerPact Breaker Cat No.
  5. HD Switch, NEMA 1 Enclosed
  6. Dual Elem Time Delay Fuse Amps
  7. Fractional HP N1 Starter Class 2510
  8. Thermal Unit
  9. Integral Starter N1 Enc 2510
  10. One Melting Alloy Thermal Unit
  11. NEMA Enclosed Starter Class 8536
  12. Thermal Unit

Notes:

Fuses and circuit breakers shown are for short-circuit ground fault protection only. This data applies to Normal Service applications of switches, starters or breakers shown.

Do not use for Heavy Service applications, as defined in the latest Catalog Digest. Data is based on information available at time of publication and is subject to change.

See actual installed equipment and Section 110-14C for termination requirements. Fuse sizes and circuit breaker trip amperes are approximate selections suitable for most installations.

Thermal unit selectors are not based on NEC currents (see NEC 430-6) but are selected from average full load currents. Thermal units can be more accurately selected using table furnished with starter and full load current marked on the motor name plate.

Software:NEMA Motor Data Calculator – Schneider Electric
Version:
Developer:Schneider Electric
Size:101 KB
Price:Free
Download:Right here | Get Download Updates | Get Technical articles
NEMA Motor Data Calculator screenshot
NEMA Motor Data Calculator screenshot

SEARCH: Articles, software & guides

Premium Membership

Premium membership gives you an access to specialized technical articles and extra premium content (electrical guides and software).
Get Premium Now ⚡

Page edited by E.C. (Google).

8 Comments


  1. Venkatesh Kaushik
    Apr 22, 2016

    Thanks for putting together this site.

    This is indeed a great resource for all those who do actual design and engineering calculations. You are THE portal to go to, and I have instructed all engineers on my team to use this site for calculations. Keep up the good work. You are the “Google” for Electrical engineers. Congratulations.


  2. eliecer
    Jun 09, 2015

    Im an electrical engineer from colombia.
    yours papers an excel programs are excellent and very useful.


  3. Fathi
    Feb 04, 2015

    Please where the reading of 380(400) Volt.
    Thanks


  4. Marikkani
    Aug 31, 2014

    Hi EEP Developers,Its been wonderful that every publish is like an Gems and useful to all.And but recent days I am inconvenient to get Downloadable Files as EEP redirects me to Time consuming or paid services to get the files

    • Edvard
      Edvard
      Aug 31, 2014

      All files are stored at Box.com – I’m speaking about good spam free file service (EEP pays a lot by the way). Download button is very clear and visible, you cannot make any mistake.

      Time consuming? Not really. Cooking is time consuming. Are you talking about 5 seconds of your life for downloading some EE guide or spreadsheet you will use for months or years?

      Should I mention that EVERYTHING is free…


  5. Shrikant Pittalwar
    Dec 06, 2013

    Pls send me soft ware of laying circuit


  6. Ramachandra.N
    Dec 06, 2013

    This site is useful which is well explained to understand

Leave a Comment

Tell us what you're thinking... we care about your opinion!

Premium Membership

Get access to premium electrical guides, technical articles and much more!