Guide To Electrical Design Of Skyscrapers
Guide To Electrical Design Of Skyscrapers

Modern electrical design //

The demands placed on the power supply of a modern skyscraper are constantly increasing. A high level of safety, flexibility throughout the entire life cycle, the integration of renewable energies and low costs are common demands nowadays that already have to be taken into consideration during the planning of a high rise building. A special challenge is the coordination of the individual electrical design installations.

The main installations are, for example, heating, ventilation, air conditioning and refrigeration, fire protection, protection against burglary, building control system and power distribution.

In modern planning, the demands on a high rise building are not simply split up among the individual installations, but have to be coordinated. An optimum solution is created from the networking of the individual requirements.

This application manual provides an overview of the installations of a high rise building that are important for the electrical power distribution and describes the basic and preliminary planning of the power distribution for an example.

The planning requirements for an energy management system for the high rise building are also integrated. Even if a building is used for 50 years or more, the significantly shorter cycles of changes in the usage, such as hotel refurbishment, new shop owners, new IT equipment in the computer centre and changes to the offices and in the life cycle of equipment and facilities require useful, long-term preliminary planning.

Network design with SIMARIS design
Network design with SIMARIS design

This application manual provides an overview of the electrical design installations of a high rise building that are important for the electrical power distribution and describes the basic and preliminary planning of the power distribution for an example.

Title: Application Models for the Power Distribution – High rise Buildings by SIEMENS
Format: PDF
Size: 7.4 MB
Pages: 96
Download: Right here | Get Download Updates | Get Technical articles
Application Models for the Power Distribution – High rise Buildings by SIEMENS
Application Models for the Power Distribution – High rise Buildings by SIEMENS

SEARCH: Articles, software & guides

Premium Membership

Premium membership gives you an access to specialized technical articles and extra premium content (electrical guides and software).
Get Premium Now ⚡

Page edited by E.C. (Google).

Leave a Comment

Tell us what you're thinking... we care about your opinion!

Premium Membership

🔌 Get access to premium electrical guides, technical articles and much more!