Faults and disturbances in low voltage networks

The short-circuit

Short-circuits are normally caused by accidental contact between two power or earth conductors. A phase-to-earth insulation fault is equivalent to a phase-to-neutral short-circuit in TN.S earthing systems.

Phase-to-neutral, phase-to-phase and phase-to-earth short-circuit
Phase-to-neutral, phase-to-phase and phase-to-earth short-circuit

The major fault categories are:

  1. Short-circuits
  2. Overloads
  3. Insulation loss.

The major disturbance categories are:

  1. Leakage currents
  2. Surges
  3. Harmonics.

Rodents can survive for a number of months, without water, feeding only on the electrical cables placed in busbar trunkings. Crawling animals, that are longer, can bring two live parts of an electrical installation into contact.

Routings of mobile cables such as those of travelling cranes, robots and automatic machines are frequently affected by short-circuits resulting from crushing or tearing or from ageing of the electrical conductor insulator. During earthwork, excavators and mechanical machinery can sever all types of electrical power supplies.


The overload

The causes of tripping of protection devices due to overloads in an electrical installation are many.

However two main causes can be identified:

1. The electrical installation changes over time and nominal current is exceeded when the number of loads increases. This is for example the case of an increase in machine installed base, number of workstations, terminals, amount of traffic, etc.

2. Loads consume more current than normal due to a malfunction, for example: clogged lifting pumps, obstructed ventilation systems, overloaded or incorrectly serviced traversers, improperly adjusted or maladjusted systems, deterioration over time of parameters leading to reduced efficiency generating increased power, etc.

AUTHOR: Schneider Electric experts

Title: Schneider Electric Low voltage expert guides – Increasing availability of LV electrical networks
Format: PDF
Size: 3.1MB
Pages: 30
Download: Right here | Get Download Updates | Get Technical articles
Increasing availability of LV electrical networks
Increasing availability of LV electrical networks

SEARCH: Articles, software & guides

Premium Membership

Premium membership gives you an access to specialized technical articles and extra premium content (electrical guides and software).
Get Premium Now ⚡

Page edited by E.C. (Google).

One Comment


  1. Edward
    Mar 03, 2015

    I love this

Leave a Comment

Tell us what you're thinking... we care about your opinion!

Premium Membership

🔌 Get access to premium electrical guides, technical articles and much more!