Photovoltaic Power Systems
Photovoltaic Power Systems (on photo: AMECO Solar Photovoltaic solar panel installation by AmecoSolar via Flickr)

This Guide

The recommended installation practices contained in this guide progress from the photovoltaic modules to the electrical outlets (in a stand-alone system) or to the utility interconnection (in a utility-interactive system).

For each component, NEC requirements are addressed, with the appropriate Code sections referenced in brackets. A sentence, phrase, or paragraph followed by a NEC reference refers to a requirement established by the NEC. The words “will,” “shall,” or “must” also refer to NEC requirements.

Suggestions based on field experience with PV systems are worded as such and will use the word “should.” The recommendations apply to the use of listed products. The word “Code” in this document refers to the 2005 NEC. In some places references will also be made to Article 690 from the 2002 NEC that have been significantly changed in the 2005 NEC.

In recent times, monetary incentives have resulted in large numbers of utility-interactive PV systems being installed. While most of these systems are purely grid-tied, many have batteries included to provide energy during blackouts, and some even include generators. With these added features, there are many similarities between the code requirements for utility-interactive systems and stand-alone systems.

In this suggested practices manual, the code requirements are addressed at the component level and at the interconnection level between components. Where unique requirements apply, they are addressed as they relate to a particular system.

Appendix A provides a limited list of sources for dc-rated and identified, or listed, products, and references to the products are made as they are discussed. Other appendices address details and issues associated with implementing the NEC in PV installations. Examples are included.

Title:Photovoltaic Power Systems
Format:PDF
Size:2.6MB
Pages:149
Download:Right here | Get Download Updates | Get Technical articles

Photovoltaic Power Systems

SEARCH: Articles, software & guides

Premium Membership

Premium membership gives you an access to specialized technical articles and extra premium content (electrical guides and software).
Get Premium Now ⚡

Page edited by E.C. (Google).

4 Comments


  1. Kamal Geagea
    Oct 22, 2014

    Dear,
    I need case studies for large scale grid connected PV systems. In addition, is there any guidance or code requirement whether the grid connection will be at LV level, MV level,etc…
    Your feedback on this issue is highly appreciated.

Leave a Comment

Tell us what you're thinking... we care about your opinion!

Premium Membership

Get access to premium electrical guides, technical articles and much more!